CALF=0, AVGS=00, ADCO=0, AVGE=0
Status and control register 3
AVGS | Hardware average select 0 (00): 4 samples averaged. 1 (01): 8 samples averaged. 2 (10): 16 samples averaged. 3 (11): 32 samples averaged. |
AVGE | Hardware average enable 0 (0): Hardware average function disabled. 1 (1): Hardware average function enabled. |
ADCO | Continuous conversion enable 0 (0): One conversion or one set of conversions if the hardware average function is enabled (AVGE=1) after initiating a conversion. 1 (1): Continuous conversions or sets of conversions if the hardware average function is enabled (AVGE=1) after initiating a conversion. |
CALF | Calibration failed flag 0 (0): Calibration completed normally. 1 (1): Calibration failed. ADC accuracy specifications are not guaranteed. |
CAL | Calibration |